I. Izinzuzo Eziyinhloko Zezokwelapha:
1. Iphephile Futhi Ihlala Isikhathi Eside: Idizayini engenamabhulashi, engenanhlansi, futhi engagugi, ifanelekela izindawo zezokwelapha ezinamazinga aphezulu e-oxygen kanye nezixazululo ezinomswakama; ukwakhiwa okuvalekile ngokuphelele, okuvikela uthuli, kanye nokumelana nokugqwala okuhlala isikhathi esingamahora angu-5,000–10,000, okunikeza ukusebenza okungenakulungiswa kanye namazinga aphansi okwehluleka.
2. Ukudlidliza Okuthule Nokuphansi: Ukulawulwa kwamagagasi e-FOC sine kuqinisekisa amazinga omsindo angu-40–45 dB kanye nokudlidliza okuncane, okulinganisela induduzo yesiguli nokunemba kokutholwa okunembile.
3. Ukuphazamiseka Okuphansi kanye Nedatha Ezinzile: I-EMI ephansi kakhulu iqinisekisa ukuthi akukho ukuphazamiseka kwamamojula okunemba njenge-ECG, i-pulse oximetry, kanye nezinzwa zokukhanya, okususa ukuzulazula kwedatha kanye nokungalingani kwesignali.
4. Isebenza ngezindlela eziningi ezimweni eziningi zokusebenza: Isekela ukunikezwa kwamandla okuphathekayo okungu-12V kanye nokunikezwa kwamandla kwesikhathi eside okungu-24V; ingahlanganiswa nebhokisi legiya le-torque ephezulu noma i-encoder ukuze ibekwe kahle, ifanele zonke izigaba zamadivayisi ezokwelapha amancane naphakathi.
II. Izicelo Zezokwelapha Eziyinhloko:
1. Imishini Yokuphefumula: Imodeli ye-24V direct-drive iyahambisana nama-nebulizer, ama-oxygen concentrator, kanye nama-ventilator alula, okwenza kube nokusebenza okuthule, okuzinzile, nokuqhubekayo kwamahora angama-24.
2. Imishini Yokulethwa Kwemithi Ngokunembile: Imodeli yokunciphisa igiya enesilinganiso esiphezulu iyahambisana namaphampu okufaka kanye namaphampu okulinganisa amancane, inikeza ukuzinza kwesivinini esiphansi kanye nokulethwa kwemithi ngokunembile; itholakala ngezinguqulo zezokwelapha ze-12V eziphathwayo kanye ne-24V.
3. Imishini Yokuvuselela Nokwelapha Ngomzimba: Amamodeli aqhutshwa yigiya elivaliwe asetshenziswa kumadivayisi okuvuselela kanye nemibhede yokudonsa, anikeza indawo eqondile kanye nokuvikelwa kokulayisha ngokweqile ukuvimbela ukulimala kwesibili; amamodeli aqhutshwa ngqo ayahambisana namadivayisi ahlukahlukene okwelapha ngomzimba wezokwelapha.
4. Imishini Yokuxilonga Enembile: Iyahambisana nemishini ye-PCR, abahlaziyi be-biochemical, kanye nama-centrifuge ezokwelapha, lawa mamodeli anokudlidliza okuphansi kanye nokuphazamiseka okuncane ukuqinisekisa idatha yokuhlola enembile nezinzile.
5. Imishini Yezokwelapha Yamazinyo Nobuhle: Imodeli ye-24V eqondisa ngqo iyahambisana nemishini yamazinyo kanye namadivayisi e-cryotherapy yezokwelapha, inikeza ukuzinza okusheshayo kanye nokuphepha kokushisa, efanelekile ezindaweni zomtholampilo ezihlanzekile.
III. Umhlahlandlela Wokukhetha Imishini Yezokwelapha Esheshayo:
1. Imishini Yokusebenza Eqhubekayo Yamahora angu-24: Inguqulo ye-TEC4260-2450 Direct-Drive
2. Amaphampu Okufutha: GMP42-TEC4260 24V (isilinganiso sejubane esingu-139–264)
3. Amadivayisi Aphathekayo Asebenzisa Ibhethri: GMP42-TEC4260 12V (isilinganiso sesivinini esiphezulu)
4. Imishini Yokubeka Ngokunembile: Inguqulo Yesivikelo Esivaliwe Se-TEC4260-E
Isikhathi sokuthunyelwe: Julayi-15-2026